Olympus resectoscope gynecology is relatively well-known in the industry. Olympus A22001A is a resectoscope produced by Olympus Corporation. As one of Olympus rigid endoscope, the Olympus 4 mm Telescopes feature renowned Olympus optics and quality craftsmanship to deliver superior surgical performance and durability. The Olympus resectoscope is designed to meet every clinical need in the field of urology.
Brand | Olympus |
Model | A22001A |
Flexibility | Rigid |
Endoscope Type | Cystoscope |
Endoscope Diameter | 4.0 mm |
View Angle | 12° |
Working Length | 28 cm |
Sterilization | Autoclavable |
Intended Use/Discipline | Urology, Emergency Medicine, Dentistry, Dental Laboratory, Cardiology, Endodontics, Cosmetology, Anesthesiology, Biological Laboratory |
Functional test report provided - Our Olympus A22001A has undergone complete performance testing, including optical clarity, sealing test and electrosurgical function verification, and test data is provided.
Transparent parts replacement record - As a reliable endoscope repair services provider, we clearly inform product information such as key parts replaced (such as lenses, seals, optical fibers).
Warranty and service commitment - We provide a 6-month warranty.
Transparent equipment source and history - All our refurbished rigid endoscopes for sale come from legal channels (such as hospital obsolete machines), without tampering with serial numbers and no history of serious damage.
Pre-cleaning immediately after use: After the operation, thoroughly rinse the Olympus A22001A channels and surfaces with sterile distilled water or a dedicated endoscope cleaning solution to prevent blood or tissue residues from drying up.
Disassembly and enzyme washing soaking: Disassemble the Olympus A22001A detachable parts (such as the scope sheath, working channel) according to the instructions, soak in a multi-enzyme cleaning solution (5-10 minutes) to remove biofilm and organic residues.
Lumen brushing and ultrasonic cleaning: Clean all lumens with a soft brush, and use a neutral pH ultrasonic cleaner for stubborn residues (avoid damage to seals and lens coatings).
High temperature sterilization or chemical disinfection: Choose high-pressure steam sterilization (134°C, 5 minutes) or Olympus-recommended glutaraldehyde/peracetic acid disinfectant to ensure sterilization compliance.
Drying and lubrication: Thoroughly dry the internal and external channels of the Olympus A22001A with a lint-free cloth and compressed air, and apply medical silicone-based lubricant to moving parts (such as adjustment knobs).
Storage and environmental control: Hang or place Olympus A22001A flat in a dedicated drying cabinet (humidity <60%), avoid bending the optical fiber or mirror body, and regularly check the aging of the sealing ring.